Discharge of a centrifugal pump is

A)
directly proportional to diameter of its impeller
B)
inversely proportional to diameter of its impeller
C)
directly proportional to (diameter)² of its impeller
D)
inversely proportional to (diameter)² of its impeller

Correct Answer : Option (C) :   directly proportional to (diameter)² of its impeller


Explanation : Discharge of a centrifugal pump is directly proportional to (Diameter)^2 of its impeller.

Head of a centrifugal pump is directly proportional to (Diameter)^2 of its impeller.

Power Developed of a centrifugal pump is directly proportional to (Diameter)^4 of its impeller.